Leak Detection bt8 east belfast

THE PROPERTY.

The house is a large detached house with red-bricked exterior, garage, and sunroom.


Technical Equipment:

Acoustic survey has been carried out using a SEWERIN STETHOPHON 04.

FLUKE TiR 32 Thermal imager.

Moisture reading with Trotec moisture meter.


Details:

On entering the house I noticed the customer showed me into the kitchen where she suspected there was a leak under the floor.  The floor looked recently tiled with large grey tiles.

On further inspection, I could see cracks and chips on four of the large tiles in the sunroom area, which also boasted.  There is also damp/moisture in the tiles joints as in the pictures.

I then took the investigation to the heating system and noticed the pressure was at zero,

I  then topped the pressure on the heating system to carry out an acoustic survey.

The acoustic survey pinpointed the leak to an area under the floor just beside the kitchen island as in the pictures below, where the microphone is positioned.


Conclusion:

A visual and an acoustic survey has concluded there was a leak from the heating system under the kitchen floor which has caused the floor tiles to crack and lift.

The floor would need to be lifted to repair the leak and carry out the drying as quite a lot of water has escaped under the floor.

The kitchen island may need to be removed and replaced to carry out said works.

Leak in tiles leak in tiles belfast

Leak detection equipment

floor leak detection equipment

CategoryLeak Detection

© 2025 BKeenan Plumbing & Heating | Privacy Policy | Web Design & SEO by SJL Digital Marketing

Plumbing Bangor County Down

    

CALL NOW
Barry Keenan Plumbing & Heating
Privacy Overview

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.